Product Details:
Payment & Shipping Terms:
|
Material: | High Chrome Alloy A05 | Type: | Horizontal |
---|---|---|---|
Use: | Mining,power | Feature: | Heavy Duty |
Principle: | Centrifugal | Color: | Blue |
High Light: | high density solids pump,sand slurry pump |
Main introduction of slurry pump
1. The primary applications for the 6/4D- metal slurry pumps are mill discharge, crusher slurry, sand
and aggregate or any coarse solids or other severe, abrasive slurries especially in the copper, gold,
iron ore, lead-zinc, coal or phosphate plants.
2. The most dramatic savings will be in these applications, though savings will also be realized on find
solids, like fine sand recovery or kaolin. The key advantage of the SH metal slurry pumps is the 10%
to 30% lower power, long even wear life and less pump downtime, which results in lowe cost-per-ton
pumped, along with better cyclone separation.
Material | High Chrome alloy A05 |
Size |
Inlet 6 inch Outlet 4 inch |
Pump Type | Single Stage Single SuctionCentrifugal slurry pumps |
Drive | ZVz/CRz/CV/DC |
Power |
Diesel or Electric |
capacity | 162-360 m3/h |
Head | 12-56 m |
Seal Type | Mechanical seal, packing seal , impeller seal |
MQQ | 1 set |
Sample Time | Within 15 days |
OEM Accepted | Yes |
Package | Free fumigation wooden cases |
Payment term | TT , west union, Money gram |
Model meaning
6/4D-
6-------Suction diameter
4-------Discharge diameter
D-------Frame type
------ Slurry pump type
Typical Applications:
Ash Handling
Cyclone Feeds
Pulp and Paper
Abrasive Slurries
Coal Preparation
Mineral Processing
Aggregate Processing
slurry pump 6/4D- flow control:
During the operation of the slurry pump, attention should be paid to the temperature and leakage of the
packing gland. Normal packing leakage should not exceed 10-20 drops per minute.
In the pump operation, if the slurry pump can take in air and it can be solid, it will make an abnormal
sound and vibrate accordingly.
In the pump operation, if the backup valve of the backup machine leaks and the switching valve is always
open, it should be noted that the backup machine is reversed due to the reverse flow.
When the pump regulates the flow during normal operation, it is not possible to reduce the flow rate by
reducing the opening of the pump suction line valve. Otherwise, the pump inlet flow will be insufficient and
the pump will cavitation.
In the pump operation, for the bearings that need cooling water, pay attention to the temperature and
quantity of water, and try to keep the bearing temperature within the specified range.
Performance table
MODEL | ALLOWABLE MATING MAX.POWER (KW) |
MATERIAL | CLEAN WATER PERFORANCE | IMPELLER | ||||||||
LINER | IMPELLER | Q Capacity | H Head | Speed | Max. Eff. | NPSH | VANES NO. | IMPELLER DIA | ||||
m3/h | L/s | (m) | n(r/min) | (%) | (m) | (mm) | ||||||
1.5/1B- | 15 | M | M | 12.6-28.8 | 3.5-8 | 6-68 | 1200-3800 | 40 | 2--4 | 5 | 152 | |
RU | RU | 10.8-25.2 | 3--7 | 7-52 | 1400-3400 | 30 | 3 | |||||
1.5/1C-HH | 30 | M | M | 16.2-34.2 | 4.5-9.5 | 25-92 | 1400-2200 | 20 | 2-5.5 | 5 | 330 | |
2/1.5B- | 15 | M | M | 32.4-72 | 9--20 | 6-58 | 1200-3200 | 45 | 3.5-8 | 5 | 184 | |
RU | RU | 25.2-54 | 7--15 | 5.5--41 | 1000-2600 | 50 | 2.5-5 | 5 | 178 | |||
3/2C- | 30 | M | M | 39.6-86.4 | 11--24 | 12-64 | 1300-2700 | 55 | 4--6 | 5 | 214 | |
RU | RU | 36-75.6 | 10--21 | 13-46 | 1300-2300 | 60 | 2--4 | 5 | 213 | |||
3/2D-HH | 60 | M | M | 68.4-136.8 | 19-38 | 25-87 | 850-1400 | 47 | 3-7.5 | 5 | 457 | |
4/3C- | 30 | M | M | 86.4-198 | 24-55 | 9-52 | 1000-2200 | 71 | 4--6 | 5 | 245 | |
RU | RU | 79.2-180 | 22-50 | 5-34.5 | 800-1800 | 59 | 3--5 | |||||
4/3E-HH | 120 | M | M | 126-252 | 35-70 | 12-97 | 600-1400 | 50 | 2--5 | 5 | 508 | |
6/4D- | 60 | M | M | 162-360 | 45-100 | 12-56 | 800-1550 | 65 | 5--8 | 5 | 365 | |
RU | RU | 144-324 | 40-90 | 12-45 | 800-1350 | 65 | 3--5 | 5 | 365 | |||
6/4S-HH | 560 | M | M | 324-720 | 90-200 | 30-118 | 600-1000 | 64 | 3-8 | 5 | 711 | |
8/6S-HH | 560 | M | M | 468-1008 | 130-280 | 20-94 | 500-1000 | 65 | 4-12 | 5 | 711 | |
8/6R- | 300 | M | M | 360-828 | 100-230 | 10-61 | 500-1140 | 72 | 2-9 | 5 | 510 | |
RU | RU | 324-720 | 90-200 | 7-49 | 400-1000 | 65 | 5-10 | 5 | 510 | |||
10/8E-M | 120 | M | M | 666-1440 | 185-400 | 14-60 | 600-1100 | 73 | 4-10 | 5 | 549 | |
10/8ST- | 560 | M | M | 612-1368 | 170-380 | 11-61 | 400-850 | 71 | 4-10 | 5 | 686 | |
RU | RU | 540-1118 | 150-330 | 12-50 | 400-750 | 75 | 4-12 | |||||
12/10ST- | 560 | M | M | 936-1980 | 260-550 | 7-68 | 300-800 | 82 | 6 | 5 | 762 | |
RU | RU | 720-1620 | 200-450 | 7-45 | 300-650 | 80 | 2.5-7.5 | |||||
14/12ST- | 560 | M | M | 1260-2772 | 350-770 | 13-63 | 300-600 | 77 | 3-8 | 5 | 965 | |
RU | RU | 1152-2520 | 320-700 | 13-44 | 300-500 | 79 | 3-10 | |||||
16/14TU- | 1200 | M | M | 1368-3060 | 380-850 | 11-63 | 250-550 | 79 | 4-10 | 5 | 1067 | |
20/18TU- | 1200 | M | M | 2520-5400 | 700-1500 | 13-57 | 200-400 | 85 | 5-10 | 5 | 1370 |
Construction Design
Tel: 86-- 031180809622
Fax: 86--031168050656